KH36 quality comments based on comments from the console log sheets, sample log sheets, bottle sample log book, salt, oxigen, nutrients analysis logs. August 11, 1999 (Igor Zhabin, POI) Codes: qflg = 4 bad value qflg = 3 suspicious value qflg = 2 good value Leg 1 (test cruise): Station 114 02 CTD 5, big Rosette Cast 01 - winch stop on way down. Wire problem. Cast 02 - some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG - 205 SiO3 too low (qflg = 3) 207 sal - low (qflg = 3) Station 115 01 CTD 5, big Rosette, bad weather, rolling, deck overflow during station. SLOG - Bottle 15 - stopcock pushed hardly. DLOG - 101 PO4 high, probably OK (qflg = 2) Station 116 01 Too rough for work with big Rosette. Wind 15 m/c. CTD 3, small Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. CTD salinity spikes in strong T gradient. SLOG - Bottle N9 broke spigot boarding, no samples. Station N 116 01 used twice in computer. Bottles NN 2, 14, 9 - leak prior to venting (when stopcock pushed in and vent closed). DLOG - 101 not enough water for salt, nuts. 102 not enough water for oxy. Salt missing. 109 not enough water for salt, nuts, oxy. 114 not enough water for salt, nuts, oxy. 102 bad salt, nuts. 104 bad all salt, nuts, oxy (qflg = 4) Edited H00 file - bottle 4 delete. Save values in H00.svd bottle 2 deleted. Save values in H00.svd. Station 117 01 CTD 3, small Rosette. CTD salinity spikes in strong T gradient. SLOG - Bottles NN 4,5,11,14 - leak prior to venting. DLOG - 111 no sample for oxy. 102 SiO3 hight (qflg = 3). 101 -salt too hight. No flush between std and sample 1 (qflg = 4). Change value on -9.0 in H00. Save value in H00.svd. Autosal - check end worm std. Use 1.99984 for end worm. Station 118 01 CTD 5, big Rosette. Bottle N15 - stopcock difficult to close. DLOG - autosal - 109 salt too hight (qflg = 4). Large difference between bath temp. and sample temp. Salt drift due to evaporation? 107 - salt too hight (qflg = 3) 102 - salt too hight (qflg = 4) Station 119 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG - autosal - 106 salt too hight (qflg = 4). Large difference between bath temp. Salt drift due to evaporation? Station 120 01 CTD 5, big Rosette. Surface - double sample for optics. Duplicate delete from H00. Save in H00.svd. DLOG - 105 SiO3 hight (qflg = 3). Station 121 01 CTD 5, big Rosette. CTD - no comment. DLOG - 102 oxy hight (qflg = 3). Station 122 01 CTD 5, big Rosette. CTD - no comment. Leg 2, northern Japan Sea Station 123 01 CTD 5, big Rosette. No record on the VCR. DLOG - 105 - salt. Diff C and S hight. Hight temp. grad. Probably OK (qflg = 2). Station 124 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG - AUTOSAL - shange bottles number in rs\12301 and rs\12301.lst. save wrong value in rs\12301.svd and rs\12301d.lst. Station 125 01 CTD 5, big Rosette. SLOG - Bottle N5 - vent did not closed Station 126 01 CTD 5, big Rosette. SLOG - Bottle N10 - stopcock broken during recovery, samples taken. DLOG - AUTOSAL files - change station number from 127 to 126 (126 - correct). Station 127 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG -AUTOSAL - Bad salt. End worm std = 2.00580. Too hight to standardize. Station 128 01 CTD 5, big Rosette. DLOG -AUTOSAL - Bad salt. End worm std = 2.00580. Too hight to standardize. Change AUTOSAL N 503 on AUTOSAL N 268. Station 129 01 CTD 5, big Rosette. No comment Station 130 01 CTD 5, big Rosette. No comment Station 131 01 CTD 5, big Rosette. No comment Station 132 01 CTD 5, big Rosette. No comment. Station 133 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG - 104 - salt hight (qflg = 3). Station 134 01 CTD 5, big Rosette. DLOG - AUTOSAL - two end worm value. Station 135 01 CTD 5, big Rosette. DLOG - 112 - salt too hight (qflg = 4). In file H00 shange on -9.0000. Save in H00.svd Station 136 01 CTD 5, big Rosette. Station 137 01 CTD 5, big Rosette. DLOG -AUTOSAL - Bad salt. End worm std = 2.00469 too hight to standardize. Edit files RS\13701 and 13701.lst for checking salinity. Original files saved as RS\13701.svd and 13701d.list. Station 138 01 CTD 5, big Rosette. DLOG -AUTOSAL - Bad salt. End worm std = 2.00469 too hight to standardize. Edit files RS\13701 and 13701.lst for checking salinity. Original files saved as RS\13701.svd and 13701d.list. Station 139 01 CTD 5, big Rosette. Station 140 01 CTD 5, big Rosette. Station 141 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG - change bottle number in rs\13901 according Small Sample Log Station 142 01 CTD 5, big Rosette. One stick of hook lost during recovery CTD. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. CTD oxygen bad. DLOG - AUTOSAL - wrong samples number from 010 to end. Change according Sample Log in rs\14701 and 14701.list files. Save old as 14701.svd and 14701d.list. Station 143 01 CTD 5, big Rosette. New CTD oxygen sensor installed before station. Station 144 01 CTD 5, big Rosette. DLOG - 103 - low salinity (qflg = 3) 101 - salinity too hight (qflg=4) Station 145 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. CTD acquisition computer error on downcast. Computer restarted as cast 2. Record in two files - 14501.raw and 14502. raw. Continous record on VCR. File 14503.raw - rewrite from VCR. DLOG - Files 14501.bot and 14502.bot save in 14501d.bot and 14502d.bot. 14502.bot renamed in 14501.bot. New 14501.bot used in H00 file. Station 146 01 CTD 5, big Rosette. DLOG - 119 - NO2 too hight (qflg=3). 120 - diff C and S too hight. Strong grad. Probably OK (qflg=2) Station 147 01 CTD 5, big Rosette. DLOG - 108 -no oxygen, bad titration. Station 148 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG - AUTOSAL - ship electricity system break during measurements. No end worm std. RS\files - 14801 -added worm end std R1=1.99979 R2=199979. Save original as 14801.svd Station 149 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG - AUTOSAL - ship electricity system break during measurements. No end worm std. New worm std after bottle 107. RS\files - 14901.svd and 14901d.lst - part down to 0107 typed handly from 14801 and 14801.lst. Files 14901 and 14901.lst after edition. Added real worm 0100 std R1=1.99979 and R2=199979. Deleted typed lines. From 0108 - real salt data. 14901.bot only 18 trips (19 OK). Duplicated 016 trip values for 017 in H00 file. Station 150 01 CTD 5, big Rosette. Rosette catch fisherman wire during recovery. DLOG - 107 - no oxy due to bad titration. Station 151 01 CTD 5, big Rosette. DLOG - 121 - no oxy due to wrong titration. Station 152 01 CTD 5, big Rosette. DLOG - autosal files RS\15201 and 15201.lst after edition. Deleted wrong lines. Save original as 15201d.lst and 15201.svd. Station 153 01 CTD 5, big Rosette. DLOG - autosal - files 15301 and 15301.lst - deleted first 0102 line (typed wrong value) and first end worm value. Save in 15301.svd and 15301d.lst. Station 154 01 CTD 5, big Rosette. Station 155 01 CTD 5, big Rosette. DLOG - autosal - 0115- deleted first 0115 line with wrong salt. Operator's mistake-first 0115=0116. Save in rs\15501.svd Station 156 01 CTD 5, big Rosette. Station 157 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. Station 158 01 CTD 5, big Rosette. DLOG - autosal - two 0115 lines. Operator's mistakes. First is wrong, deleted. Save in RS\15801.svd Station 159 01 CTD 5, big Rosette. Double sample for optics near surface. Duplicate delete from H00. Save in H00.svd. Station 160 01 CTD 5, big Rosette. SLOG - Bottle 24 close in air Wire damaged, cut dangerous part. Records on VCR stop during station. DLOG - salt sample bottles N 7, 17 brouken. Station 161 01 CTD 5, big Rosette. Station 162 01 CTD 5, big Rosette. SLOG - altimetr did not work. DLOG - 102 - salt hight (qflg=3) 112 - salt hight (qflg=3) 116 - salt low (qflg=3) Station 163 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. (ldt 10/10/99: DAB in sum file must be wrong - says close to bottom but station ends at about 2000) Station 164 01 CTD 5, big Rosette. Station 165 01 CTD 5, big Rosette. DLOG - Autosal - St. 165 processed as 164. Rename files rs\ 16401 in 16501. Change number of station and box number. Save in rs\16501.svd and 16501d. lst. Station 166 01 CTD 5, big Rosette. DLOG - Autosal - Operator's mistake. Change box number from 003 on 004 according Sample Log Sheet. bottle 12 - SiO3 low (qflg = 3). Station 167 01 CTD 5, big Rosette. Station 168 01 CTD 5, big Rosette. Station 169 01 CTD 5, big Rosette. Station 170 01 CTD 5, big Rosette. DLOG - 105 NO3 low. Local oxy max. Probably OK (qflg=2) Station 171 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. Station 172 01 CTD 5, big Rosette. DLOG - salt 108 - lid broken (qflg=4). 104 - salt hight (qflg=3) Station 173 01 CTD 5, big Rosette. SLOG - bottle N 18 -no sample for nutrients. 07 08 1999 - Computer virus "monkey" find on OXY f-disk. Cheking all f-disks and this computer. No virus. Station 174 01 CTD 5, big Rosette. Station 175 01 CTD 5, big Rosette. SLOG - altimetr did not work. Station 176 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. DLOG 114 -no oxy. (note that DAB in sum file is wrong - station does not go to bottom 10/9/99 ldt) Station 177 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. Station 178 01 CTD 5, big Rosette. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. SLOG - freons -bottle N6 -lid broken salinity - two end worm std. First deleted, save in rs\17801.svd. Station 179 01 CTD 5, big Rosette. DLOG - 102 -oxy hight (qflg=4) Station 180 01 CTD 5, big Rosette. SLOG - Noble G from bottle N5 -tube broken. Samples from bottle N6. Some double samples for optics. Duplicates delete from H00. Save in H00.svd. Station 181 01 CTD 5, big Rosette. Station 182 01 CTD 5, big Rosette. Surface double sample for optics. Duplicates delete from H00. Save in H00.svd. SLOG - Before St. 182 change position of bottles N 1 and 2 on Rosette. Bottle N 1 replace on place N 2, bottle N2 on N 1. Change bottles mark. Station 183 01 CTD 5, big Rosette. Station 184 01 CTD 5, big Rosette. Station 185 01 CTD 5, big Rosette. SLOG - Bottle N 10 air leak prior to venting. Station 186 01 CTD 5, big Rosette. Station 187 01 CTD 5, big Rosette. Station 188 01 CTD 5, big Rosette. Station 189 01 CTD 5, big Rosette. Station 190 01 CTD 5, big Rosette. CTD only. (WHY??? any log book notes? ldt 9/10/99) Use this cast since cast 3 has bad offsets Station 190 02 CTD 5, big Rosette. Only CTD - Upcast from 1850 m. No confirm after bottle N 7. No sampling, station repited as cast 3. Station 190 03 CTD 5, big Rosette. CTD conductivity offset downcast. (NOTE LDT 9/10/99: offset is 1090-1136 and 1232-1304 - Use CAST 1! Looks like slime.) Station 191 01 CTD 5, big Rosette. Surface double samples for optics. Duplicates delete from H00. Save in H00.svd. Station 192 01 CTD 5, big Rosette. CTD - winch stop upcast Surface double samples for optics. Duplicates delete from H00. Save in H00.svd. Station 193 01 CTD 5, big Rosette. Surface double sample for optics. Duplicates delete from H00. Save in H00.svd. SLOG - Bottle N15 -no confirmation at 400 db? (did not push fair button ?). Bottle N 15 close at 300 db. CTD - winch stop upcast Station 194 01 CTD 5, big Rosette. SLOG - vent of bottle N 2 did not close strongly, leak slightly. DLOG - oxy bottle N 1 hight (qflg=4). Station 195 01 CTD 5, big Rosette. Station 196 01 CTD 5, big Rosette. CTD - Bottle N 1 and 2 - no confirmations on SBE deck unit. Change SBE unit. Open upcast file 19602. Station 196 02 CTD 5, big Rosette. Surface double sample for optics. Duplicates delete from H00. Save in H00.svd. SLOG - CTD upcast. Bottle 1 - no comfirmation. DLOG - salt, oxygen, nutrients processed as ...19601... Change files name and cast number in files. DLOG - Bottles N 1,2,3 -same depth, oxy diffrent. Station 197 01 CTD 5, big Rosette. Surface double sample for optics. Duplicates delete from H00. Save in H00.svd. Station 198 01 CTD 5, big Rosette. Station 199 01 CTD 5, big Rosette. Station 200 01 CTD 5, big Rosette. SLOG - N 2,4,6 - double samples for oxygen. Station 201 01 CTD 5, big Rosette. Station 202 01 CTD 5, big Rosette. Station 203 01 CTD 5, big Rosette.